Naar de inhoud springen Naar het navigatiemenu springen

Eugenol methyl ether

ROTICHROM® GC
Mogelijke gevolgen: leiden tot schade aan de gezondheid, irriteren organen, huid of luchtwegen. Leiden in grotere hoeveelheden tot de dood. Veiligheid: zoals hierboven; bij huidirritaties of oogcontact met water of geschikt middel spoelen.
Mogelijke gevolgen: zijn voor waterorganismen schadelijk, giftig of zeer giftig, acuut of met langdurige werking. Veiligheid: alleen met gevaarlijk afval afvoeren, in geen geval in het milieu laten terechtkomen.
Warning
H302-H319-H411
i harmful if swallowed, causes serious eye irritation, toxic to aquatic life with long lasting effects
P270 P273 P305+P351+P338 P337+P313
i do not eat, drink or smoke when using this product, avoid release to the environment, IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing, if eye irritation persists: Get medical advice/attention
VE
Verp.
4-Allyl-1,2-dimethoxybenzene
Empirical formula C11H14O2
Molar mass (M) 178,23 g/mol
Density (D) 1,04 g/cm³
Boiling point (bp) 255 °C
Flash point (flp) 110 °C
Melting point (mp) -4 °C
Storage temp. +4 °C
ADR 9 III
WGK 1
CAS No. [93-15-2]
EG-Nr. 202-223-0
UN-Nr. 3082

Reference substance for GC.

Type analysis

88,05 €/VE 

Excl. btw | 1 g Per VE

Bestelnr. 5073.1

Op voorraad
Vrij van verzendingskosten vanaf 125 €
Snelle en betrouwbare levering!
Vanaf 6 VE 83,65 €/VE
Vanaf 24 VE 79,24 €/VE
Carl Roth abonnementservice

Now recurring orders conveniently delivered as a subscription!

With the new Carl Roth Replenishment Service you can let products be ordered automatically which you need regularly in your lab!

How it works:
1

Put all products for your subscription in the desired quantity in the basket.

2

In the shopping cart, select the option "Order shopping cart as subscription" Order as subscription.

3

Set Starty point and interval for your subscription and submit order!

By the way: Through your account you can customize or delete your subscriptions anytime.

Vragen over dit product?

Do you have a question about this product?

In the general information or Product details, we have compiled extensive descriptions and downloads for each product.
If you can not find an answer to your question in the Certificates of Analysis and Application Examples , feel free to contact us!
Neem contact op met service
Eugenol methyl ether
Geselecteerde hoeveelheid:   0
  1. Tussentotaal:  0.00
Bestelnr. VE Verp. Prijs Hoeveelheid
5073.1 1 g plastic 88,05 €
Op voorraad
Binnenkort beschikbaar
Niet beschikbaar
Leveringsdatum onbekend op dit moment
Geselecteerde hoeveelheid:   0
  1. Tussentotaal:  0.00

Downloads


Algemene informatie

Reference Substances ROTICHROM® HPLC/TLC/GC

for Chromatography

Pure reference substances are essential for precise analysis. They are used for identifying compounds by retention time, for calibrating detectors, and for eliminating errors in quantification of the sample compounds.

Peak areas are proportional to sample quantity in all chromatographic methods. For precise quantitative analysis, however, it is necessary to calibrate the detector as the signal may significantly vary with different substances.

To avoid errors during sample preparation and injection, an internal standard should be used in any case. The standard must not be present in the sample, however, its chemical and physical properties ought to be the closest possible to the analytical targets. It must be well resolved in the chromatogram within the same range of retention time as the sample. Before sample analysis, a given volume of standard is added, and all clean‑up procedures are made with the sample containing the standard. Quantitative errors may be compensated by comparing the peak‑areas of the sample with that of the internal standard.

Reference Substances for GC

ROTICHROM® GC

Carl ROTH offers an extensive range of reference substances for gaschromatography from the substance groups of alkanes, alcohols, ketones, esters, aromatic compounds, and much more. Their GC purity allows an accurate analysis.

The ROTICHROM® GC substances come with a certificate of analysis and a GC chromatogram enclosed in the outer packaging.

Reference Substances ROTICHROM® HPLC/TLC/GC

for Chromatography

Pure reference substances are essential for precise analysis. They are used for identifying compounds by retention time, for calibrating detectors, and for eliminating errors in quantification of the sample compounds.

Peak areas are proportional to sample quantity in all chromatographic methods. For precise quantitative analysis, however, it is necessary to calibrate the detector as the signal may significantly vary with different substances.

To avoid errors during sample preparation and injection, an internal standard should be used in any case. The standard must not be present in the sample, however, its chemical and physical properties ought to be the closest possible to the analytical targets. It must be well resolved in the chromatogram within the same range of retention time as the sample. Before sample analysis, a given volume of standard is added, and all clean‑up procedures are made with the sample containing the standard. Quantitative errors may be compensated by comparing the peak‑areas of the sample with that of the internal standard.

Reference Substances for GC

ROTICHROM® GC

Carl ROTH offers an extensive range of reference substances for gaschromatography from the substance groups of alkanes, alcohols, ketones, esters, aromatic compounds, and much more. Their GC purity allows an accurate analysis.

The ROTICHROM® GC substances come with a certificate of analysis and a GC chromatogram enclosed in the outer packaging.

Analysecertificaten

Hier kunt u uw analysecertificaat voor het geselecteerde product zoeken en downloaden. Geef een chargenummer op.
De volgende analysecertificaten werden gevonden:

Type analysis

Purity (GC)≥95 %  

0 Beoordelingen

0.0 van 5 sterren