Jump to content Jump to navigation menu

High-pressure laboratory autoclaves model 0 Accessories for gas injection

From  Carl ROTH


50 ml/100 barModel 0 is the smallest autoclave in the ROTH range. Initially it was developed for preliminary tests at room temperature. It is the steel test tube for all preliminary tests where work is carried out under high pressure. It is the ideal and cost-effective alternative for situations where glass carius tubes may present a danger. Model 0 has a screw-on head with a threaded opening for fitting to equipment. The opening can be closed with a screw stopper. Sealed with PTFE gaskets (max. 180 °C) or pure silver gaskets (max. 300 °C). Depending on the scope of the autoclave system, delivery times may apply!
Product details

excl. VAT.

Art. No. 337908

Product details


50 ml/100 barModel 0 is the smallest autoclave in the ROTH range. Initially it was developed for preliminary tests at room temperature. It is the steel test tube for all preliminary tests where work is carried out under high pressure. It is the ideal and cost-effective alternative for situations where glass carius tubes may present a danger. Model 0 has a screw-on head with a threaded opening for fitting to equipment. The opening can be closed with a screw stopper. Sealed with PTFE gaskets (max. 180 °C) or pure silver gaskets (max. 300 °C). Depending on the scope of the autoclave system, delivery times may apply!



High-pressure laboratory autoclaves model 0 Accessories for gas injection 

High-pressure laboratory autoclaves model 0 Accessories for gas injection
Selected quantity:   0
  1. Subtotal:  0.00
Art. No. Price Quantity
337908
In stock
In procurement
No longer available
Delivery date currently unknown
Selected quantity:   0
  1. Subtotal:  0.00

Downloads / MSDS

General information

OVERVIEWHigh-pressure laboratory autoclaves from ROTH

Model 0 Model I Model II Model IV
Max. working volume (ml) 50 100 200 300 250 500
Max. working pressure (bar) 100 100 100 100 200 100
Heating mantle none 10 S 20 S 30 S 30 S 50 S
Sampling possible no no yes yes
Stirrer connection possible no no yes yes
Temp. measurement in autoclave possible no no yes yes

Attention

Due to the shape of the screw thread, cold setting of cylinder and head is possible when screwing these on. This usually leads to them sticking when opening and the thread breaking as a result.The conducted reaction necessitates coating the thread with a release agent such as PTFE spray (Art. No. K007.1).Warning: Do not use PTFE screw thread tape!


Advice for working with silver gaskets

When working with silver gaskets, it is essential to tighten the screw threads very tightly to achieve the necessary seat. We therefore recommend annealing the silver gaskets at +850 °C before use - the gaskets remain softer and more pliable, even when cool, and seal more efficiently.