Technical Data Sheet
Acetone
Molar mass (M) 58,08 g/mol
Density (D) 0,79 g/cm³
Boiling point (bp) 56,05 °C
Flash point (flp) -17 °C
Melting point (mp) -94,8 °C
ADR 3 II
WGK 1
CAS No. 67-64-1
EG-Nr. 200-662-2
UN-Nr. 1090
€62.65/Pack Qty. Campaign price!
excl. VAT. | 2.5 l per Pack Qty.
Art. No. 7535.1
Product details
Acetone ROTISOLV® Pestilyse® plus ≥99,9 %
Water miscibility | yes |
- Subtotal: 0.00
Art. No. | Pack Qty. | Pack. | Price | Quantity | |
---|---|---|---|---|---|
7535.1 | 2.5 l | glass |
€78.40
€62.65 |
|
|
In stock
In procurement
No longer available
Delivery date currently unknown
|
- Subtotal: 0.00
Downloads / MSDS
General information
Further attractive products to complete your chromatography laboratory can be found on our Chromatography page!
The hydrocarbon index is defined as the total of all organic substances that can be extracted with hexane, but cannot be adsorbed in Florisil® (magnesium silicate). On a covalent GC column, these elute between n-decane and n-tetracontane and have a boiling range of 175-525 °C. These include heating oils, diesel fuels, kerosene, lubricants and transmission fluids. Petrols are not detected using this method. Carl ROTH offers an extensive range of products for the determination of the hydrocarbon index in accordance with EN ISO 9377-2-Mod. (DIN H53).
Standards
According to EN ISO 9377-2-Mod. (DIN H53)
- Manufactured in accordance with ISO 17034 in an accredited environment
- Tested in a laboratory accredited to ISO/IEC 17025
- Ideal for calibration of GC-FID, GC-TCD, GC-ECD, GC-MS, GC-MS/MS, LC-UV, LC-MS and LC-MS/MS
- With an detailed, batch-related certificate of analysis
for determination of dioxines, furanes, PCBs, pesticides, hydrocarbons and further pollutants
Carl ROTH created this product line (ROTISOLV® Pestilyse® plus) especially to address the growing requirements in residue analysis. Several relevant parameters are specified for these solvents which allow the use in various applications. With this product line, Carl ROTH sets the benchmark for residue analysis solvents in terms of purity and quality.
Properties:
- Highest purity
- Controlled by FID, ECD and NP
- PAH tested
- Tested for hydrocarbons C14-C40
- Tested for fluorescence
- Volatile impurities: max. 5 ppm
- Non-volatile impurities: max. 5 ppm
Certificates of Analysis
Guarantee analysis
Assay (GC) | ≥99.9 % |
Colour (APHA) | ≤10 |
Water (KF) | ≤0.3 % |
Free acid (as CH3COOH) | ≤0.002 % |
Evaporation residue | ≤0.0003 % |
GC/FID suitability (as 2-octanol) | ≤10 ng/ml |
GC/ECD suitability (as heptachloro epoxide) | ≤10 ng/l |
GC/ECD dioxins, furans and PCBs (as lindane) | ≤5 ng/l |
GC/ECD pesticides (as lindane) | ≤5 ng/l |
GC/NPD pesticides (as parathion) | ≤10 ng/l |
Oil index (any hydrocarbon C10-C40) | ≤0.1 mg/l |
GC/ECD volatile impurities (as ethylene dibromide) | ≤5 ng/ml |
PAH-test (less than 2 ppb, HPLC) | complies |
Fluorescence (as quinine) | |
254 nm | ≤1 ppb |
365 nm | ≤1 ppb |