Jump to content Jump to navigation menu

Combi hand-held measuring device SensoDirect 150

From  Tintometer
Sensor


For measuring pH, Redox, conductivity, TDS, oxygen and temperature.
Product details

€734.35/Pack Qty. 

excl. VAT. | 1 unit(s) per Pack Qty.

Art. No. YT94.1

In stock
Delivery fast, simple and reliable!
from 6 Pack Qty. €697.63/Pack Qty.
from 24 Pack Qty. €660.92/Pack Qty.

Product details


For measuring pH, Redox, conductivity, TDS, oxygen and temperature.

  • Automatic/manual temperature compensation
  • Min/Max and Hold functions
  • Saves up to 16,000 data sets automatically/manually
  • Auto Off after 10 min


Combi hand-held measuring device SensoDirect 150 

Delivery incl. pH plastic electrode with gel electrolyte, external temperature gauge, conductivity probe, buffer solutions (pH 4/7), plastic case and batteries. Without oxygen sensor and Redox electrode; please order separately.
Technical Information
Type SensoDirect 150 
Parameters pH 
redox 
conductivity 
TDS 
oxygen 
temperature 
Channels
Sensor 226 (pH), LC 8 (EC) 
pH measuring range 0 to 14 
pH resolution 0,01 pH 
pH accuracy ±0.02 pH 
pH temp. compensation automatic: 0 to +65 °C, manual: 0 to +100 °C 
Voltage measuring range -1999 to +1999 mV
Voltage resolution 1 mV mV
Voltage accuracy ±1 mV
Conductivity measuring range 0.2 to 200 mS/cm
Conductivity resolution automatic (0.001 S/cm - 0.1 mS/cm) 
Conductivity accuracy ±0.01 mS/cm (0.200 to 2.000 mS) 
±0.1 mS/cm (2.01 to 20.00 mS) 
±1 mS/cm (20.1 to 200.0 mS) 
Temperature compensation conductivity Automatic: 0 to +60 °C 
TDS measuring range 0 to 132000 ppm
TDS resolution 0.1 ppm (0 to 132 ppm) 
1 ppm (132 to 1320 ppm) 
10 ppm (1320 to 13,200 ppm) 
100 ppm (13,200 to 132,000 ppm) 
TDS accuracy 2.64 ppm (0 to 132 ppm) 
26.4 ppm (132 to 1320 ppm) 
264 ppm (1320 to 13,200 ppm) 
2640 ppm (13,200 to 132,000 ppm) 
O2 concentration measuring range 0 to 20 mg/l 
O2 saturation concentration ±0.4 mg/l 
O2 saturation measuring range 0 to 100% 
O2 saturation accuracy ±0.7 % 
O2 resolution 0.1 mg/l 
0.1 % 
O2 temp. compensation automatic: 0 to +50 °C 
Salt correction 0 - 39 %
Air pressure compensation 0 - 8900 m
Calibration points 1/2/3 (pH, EC), 1 (Redox) 
Data memory 16000 data sets 
Connection BNC (pH) 
L x W x H 220 x 120 x 40 mm
Weight 625 g
Power supply 4x battery Mignon/AA 1.5 V 
Combi hand-held measuring device SensoDirect 150
Selected quantity:   0
  1. Subtotal:  0.00
Art. No. Sensor Pack Qty. Price Quantity
YT94.1 226 (pH), LC 8 (EC) 1 unit(s)

€734.35

In stock
Available
In procurement
No longer available
Delivery date currently unknown
Selected quantity:   0
  1. Subtotal:  0.00

Downloads / MSDS

General information

The redox potential can be measured with a pH meter, which can display mV values.A redox probe is needed for this.