Combi table-top multimeter PC 50 VioLab

From  Dostmann
Sensor


For measuring pH, Redox, conductivity, TDS and temperature.
Product details

€827.75/Pack Qty. 

excl. VAT. | 1 unit(s) per Pack Qty.

Art. No. HXC0.1

In procurement
from 6 Pack Qty. €786.36/Pack Qty.
from 24 Pack Qty. €744.98/Pack Qty.

Product details


For measuring pH, Redox, conductivity, TDS and temperature.

  • Large LCD display, backlit with simultaneous display of measured value and temperature
  • Automatic and manual temperature compensation
  • Automatic calibration with display of the calibrated ranges, storage of current calibration
  • Manual calibration possible with user-defined buffer
  • Confirmation when a stable measured value is reached
  • Adjustable reference temperature, cell constant and temperature coefficient

  • 201T pH single-rod measuring cell with integrated temperature gauge for common aqueous samples. pH range: 0 to 14. Operating temperature 0 to +60 °C. Ceramic diaphragms, gel electrolyte, plastic shaft. Shaft length/Ø: 120/12 mm
  • 2301T conductivity sensor with integrated temperature gauge. Measuring range: 10 μS to 200 mS/cm. Operating temperature: 0 to +60 °C. Steel shaft, length/Ø: 120/12 mm


Combi table-top multimeter PC 50 VioLab 

Delivery incl. 201T pH single-rod measuring cell, 2301T conductivity sensor, buffer solutions (pH 4.01/7.00; EC 1413 μS/cm / 12.88 mS/cm), storage solution, electrode holder and mains adapter.
Technical Information
Type PC 50 VioLab 
Parameters pH 
redox 
conductivity 
TDS 
temperature 
Channels
Sensor 201T (pH), 2301T (EC) 
pH measuring range 0 to 14 
pH resolution 0,01 pH 
pH accuracy ±0.01 pH 
Voltage measuring range -1000 to +1000 mV
Voltage resolution 1 mV
Voltage accuracy ±1 mV
Conductivity measuring range 0 µS/cm to 200 mS/cm mS/cm
Conductivity resolution automatic (0.01 μS/cm - 0.1 mS/cm) 
Conductivity accuracy ±0.4 μmS/cm (0 to 19.99 μmS/cm) 
±4 μmS/cm (20.0 to 199.9 μmS/cm) 
±40 μS/cm (200 to 1999 μS/cm) 
±0.4 mS/cm (2.00 to 19.99 mS/cm) 
±4 mS/cm (20.0 to 200.0 mS/cm) 
Reference temperature conductivity +15 - +30 °C
Temperature coefficient 0 - 10,00 % / °C 
Cell constant 0,1 / 1,0 / 10 cm-1 
TDS measuring range 0 mg/l to 100 g/l ppm
TDS resolution automatic (0.01 mg/l - 0.1 g/l) 
TDS accuracy ±0.2 mg/l (0 to 19.99 mg/l) 
±2 mg/l (20.0 to 199.9 mg/l) 
±20 mg/l (200 to 1999 mg/l) 
±0.2 g/l (2.00 to 19.99 g/l) 
±1 g/l (20.0 to 100.0 g/l) 
Temperature measuring range 0 to +100 °C
Temperature resolution 0.1 °C 
Temperature accuracy ±0.5 °C 
Calibration points 1/2/3 (pH), 1/2/3/4 (EC) 
Connection BNC (pH) 
BNC (EC) 
Cinch (°C) 
L x W x H 160 x 185 x 70 mm
Weight 550 g
Mains connection 100-240 V, 50/60 Hz 
Combi table-top multimeter PC 50 VioLab
Selected quantity:   0
  1. Subtotal:  0.00
Art. No. Sensor Pack Qty. Price Quantity
HXC0.1 201T (pH), 2301T (EC) 1 unit(s)

€827.75

In stock
Available
In procurement
No longer available
Delivery date currently unknown
Selected quantity:   0
  1. Subtotal:  0.00

Downloads / MSDS


General information

The redox potential can be measured with a pH meter, which can display mV values.A redox probe is needed for this.