Jump to content Jump to navigation menu

ROTIPHORESE®Gel 40 (19:1), 1 l

ROTIPHORESE® 40 %, ready-to-use, gas-stabilized
Icon_EVE-EUD Please consider that this product might be liable to some legal sanctions as for example to obtain an end user declaration or the prohibition of some applications. For details please do contact your counterpart in our sales department!
Icon_ready-to-use Ready-to-use products and reagents
Examples of effect: In smaller quantities, lead to immediate serious damage to health or death. Safety: Do not inhale, touch or swallow. Wear work safety equipment. Call a poison control centre or doctor immediately. Recovery position.
Examples of effect: Have an allergenic effect, carcinogenic, mutagenic, toxic to reproduction and cause developmental toxicity (reprotoxic) or damage to organs Safety: You must be well-informed before starting work with these substances; wear protective clothing and gloves, eye protection and mask or breathing protection.
Danger
H301-H315-H317-H319-H332-H340-H350-H361f-H372
i toxic if swallowed, causes skin irritation, may cause an allergic skin reaction, causes serious eye irritation, harmful if inhaled, may cause genetic defects, may cause cancer, suspected of damaging fertility, causes damage to organs through prolonged or repeated exposure
P201 P280 P301+P310 P302+P352 P305+P351+P338 P308+P313
i obtain special instructions before use, wear protective gloves/eye protection, IF SWALLOWED: Immediately call a POISON CENTER/doctor, IF ON SKIN: Wash with plenty of soap and water, IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing, IF exposed or concerned: Get medical advice/attention
Related products
Pack Qty.
Pack.
Gel solution, PAGE gel solutions
Density (D) 1,03 g/cm³
Storage temp. +4 °C
ADR 6.1 III
WGK 3
UN-Nr. 3426

Aqueous acrylamide and bisacrylamide stock solution at a ratio of 19:1 for preparation of DNA gels.
Optimal for DNA gels for separation of small fragments, manual sequencing and automatic sequencers. Cross linking 5.

Ready-to-use, gas-stabilized ready-to-use acrylamide solutions with different concentrations and rat ...
Product details

€80.55/Pack Qty. 

excl. VAT. | 1 l per Pack Qty.

Art. No. 3030.1

In stock
Delivery fast, simple and reliable!
from 6 Pack Qty. €76.52/Pack Qty.
from 24 Pack Qty. €72.50/Pack Qty.
Carl Roth subscription service

Now recurring orders conveniently delivered as a subscription!

With the new Carl Roth Replenishment Service you can let products be ordered automatically which you need regularly in your lab!

How it works:
1

Put all products for your subscription in the desired quantity in the basket.

2

In the shopping cart, select the option "Order shopping cart as subscription" Order as subscription.

3

Set Starty point and interval for your subscription and submit order!

By the way: Through your account you can customize or delete your subscriptions anytime.

Any questions about this product?

Do you have a question about this product?

In the general information or Product details, we have compiled extensive descriptions and downloads for each product.
If you can not find an answer to your question in the Certificates of Analysis and Application Examples , feel free to contact us!
Contact Service

Product details


Ready-to-use, gas-stabilized ready-to-use acrylamide solutions with different concentrations and ratios of acrylamide to bisacrylamide. The ROTIPHORESE® gel solutions are very easy to use and enable reproducible and high-resolution gel electrophoresis.


Directions for use

ROTIPHORESE® gel solutions can be used for protein and nucleic acid separation in PAGE gels. The high-purity solutions can be combined with any buffer system. During sequencing, they facilitate the preparation of sequencing gels of consistent quality; our fluorescence-free gel solutions are recommended for the use of automatic sequencers.


Please note

The ROTIPHORESE®acrylamide and bisacrylamide solutions from Carl ROTH are produced only from acrylic acid-free substances and are strictly controlled in acrylamide content and pH. Oxidation products are removed from the solution by a selective absorption process. Their new formation and the polymerization of the solution are prevented by stabilizing the solution with inert gas.
In order to ensure a high lot-to-lot consistency of our ROTIPHORESE® solutions, each batch is subjected to an electrophoretic test. Fluorescence-free gel solutions are tested for suitability for automatic sequencers.


Recommendation for Use of ROTIPHORESE® Ready-Made Gel Solutions

Analysis of Gel solution Art. No.
Proteins/peptides >15 kDa, DNA fragments Gel 30 (37,5:1) 3029.1
Gel 40 (37,5:1) T802.1
Proteins/peptides <30 kDa and DNA oligonucleotides Gel 40 (29:1) A515.1
DNA sequences (manual sequencing) ROTIPHORESE®DNA sequencing system A431.1
Gel 40 (19:1) 3030.1
DNA sequences (short-run automat. sequencing) NF solution 40 % (19:1) A516.1
DNA sequences (long-run automat. sequencing) NF solution 30 % (29:1) A124.1
NF solution 40 % (29:1) A121.1

The right choice for each and every application
The large variety of different ROTIPHORESE® solutions provides you with the right product for each and every application. ROTIPHORESE® gel solution may be used both in protein and nucleic acid electrophoresis. ROTIPHORESE® ready-to-use solutions for manual sequencing facilitate the preparation of sequencing gels of a constant high quality - also suitable for automatic sequencers.

Safe
Acrylamide ia a strong nerve poison which has clearly proved to be carcinogenic and to change the genetic make-up during animal testing. Acrylamide is resorbed primarily through the skin. The formation of dust when working with the solid matter is particularly critical. A hazard which can be easily avoided by using the ROTIPHORESE® ready-to-use solution.

Superior quality
ROTIPHORESE® Acrylamide and -Bisacrylamide solutions from Carl ROTH have the highest purity level. They are produced from substances free from acrylic acid. Oxidation products are removed from the solution by a selective absorption process. A new formation of such and/or polymerisation of the solution is prevented by gaseous stabilisation of the solution.
In order to guarantee a high consistency of our ROTIPHORESE®-solutions, each batch undergoes electrophoretic testing.


Safe
Acrylamide ia a strong nerve poison which has clearly proved to be carcinogenic and to change the genetic make-up during animal testing. Acrylamide is resorbed primarily through the skin. The formation of dust when working with the solid matter is particularly critical. A hazard which can be easily avoided by using the ROTIPHORESE® ready-to-use solution.

Superior quality
ROTIPHORESE® Acrylamide and -Bisacrylamide solutions from Carl ROTH have the highest purity level. They are produced from substances free from acrylic acid. Oxidation products are removed from the solution by a selective absorption process. A new formation of such and/or polymerisation of the solution is prevented by gaseous stabilisation of the solution.
In order to guarantee a high consistency of our ROTIPHORESE®-solutions, each batch undergoes electrophoretic testing.


• For preparing 4-20 % sequencing gels
• No tedious dissolving of urea
• Prevents acrylamide dusts
• Simple handling



ROTIPHORESE®Gel 40 (19:1) ROTIPHORESE® 40 %, ready-to-use, gas-stabilized

Cross linking 5.



ROTIPHORESE®Gel 40 (19:1)
Selected quantity:   0
  1. Subtotal:  0.00
Order No. Pack Qty. Pack. Price Quantity
3030.1 1 l glass €80.55
3030.2 250 ml glass €33.25
In stock
Available at short notice
Not available
Delivery date currently unknown
Selected quantity:   0
  1. Subtotal:  0.00

Downloads


General information

Recommendation for Use of ROTIPHORESE® Ready-Made Gel Solutions

Analysis of Gel solution Art. No.
Proteins/peptides >15 kDa, DNA fragments Gel 30 (37,5:1) 3029.1
Gel 40 (37,5:1) T802.1
Proteins/peptides <30 kDa and DNA oligonucleotides Gel 40 (29:1) A515.1
DNA sequences (manual sequencing) ROTIPHORESE®DNA sequencing system A431.1
Gel 40 (19:1) 3030.1
DNA sequences (short-run automat. sequencing) NF solution 40 % (19:1) A516.1
DNA sequences (long-run automat. sequencing) NF solution 30 % (29:1) A124.1
NF solution 40 % (29:1) A121.1

Certificates of Analysis

You can search for and download your certificate of analysis for the selected product here. Please provide your batch number.
The following analysis certificates have been found: