Jump to content Jump to navigation menu

ROTISZINT®Routine, 500 ml

ROTISZINT® ready-to-use, NPE free, for scintillation
Icon_ready-to-use Ready-to-use products and reagents
Examples of effect: Damage metals and burn body tissues; may cause serious eye damage. Safety: Avoid contact; wear safety spectacles and gloves. In the event of contact with eyes and skin, rinse with water.
Examples of effect: Have an allergenic effect, carcinogenic, mutagenic, toxic to reproduction and cause developmental toxicity (reprotoxic) or damage to organs Safety: You must be well-informed before starting work with these substances; wear protective clothing and gloves, eye protection and mask or breathing protection.
Examples of effect: Are harmful to aquatic organisms, toxic or highly toxic, acute or with long-term effects. Safety: To be disposed of as hazardous waste only, do not allow into the environment under any circumstances.
Danger
H304-H315-H318-H410
i may be fatal if swallowed and enters airways, causes skin irritation, causes serious eye damage, very toxic to aquatic life with long lasting effects
P280 P301+P310 P302+P352 P305+P351+P338
i wear protective gloves/eye protection, IF SWALLOWED: Immediately call a POISON CENTER/doctor, IF ON SKIN: Wash with plenty of water, IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing
Related products
Pack Qty.
Pack.
Scintillation cocktail
Density (D) ~1 g/cm³
Boiling point (bp) >290 °C
Flash point (flp) 149 °C
Melting point (mp) <-30 °C
Storage temp. +15 to +25 °C
ADR 9 III
WGK 3
UN-Nr. 3082

LSC cocktail, for scintillation assays in general

Multi-purpose, ready-to-use scintillation cocktails for Liquid Scintillation Counting (LSC) of β radiators (e.g. 3H, 14C, 32P, 35S) in aqueous samples. NPE-free
Product details

€57.95/Pack Qty. 

excl. VAT. | 500 ml per Pack Qty.

Art. No. 1P1A.1

In stock
Delivery fast, simple and reliable!
from 6 Pack Qty. €55.05/Pack Qty.
from 24 Pack Qty. €52.16/Pack Qty.

Product details


Multi-purpose, ready-to-use scintillation cocktails for Liquid Scintillation Counting (LSC) of β radiators (e.g. 3H, 14C, 32P, 35S) in aqueous samples. NPE-free

  • High counting efficiency
  • Very good quench resistance
  • High flash point
  • NPE free
  • Biodegradable
  • Non-carcinogenic
  • According to 2003/53/ECC

The next generation ROTISZINT® Cocktails have been developed to replace nonylphenylethoxylates (NPE) with more user-friendly, sustainable reagents. In addition, these modern cocktails show even higher scintillation efficiency and higher sample holding capacity. ROTISZINT® cocktails are also biodegradable and pleasant to use due to their high flash point.
ROTISZINT® scintillation cocktails may be used in all biological, biochemical and chemical areas. Typical applications are, for instance, the measurement of cell culture supernatants, routine analysis, enzymatic or flow-count assays in the field of research, development or analytics.

The cocktails are according to Directive 2003/53/ECC of the European Parliament and Council


Directions for use

Wide excitation range between 190 and 370 nm
Emission maximum: 420-430 nm

Our modern ROTISZINT® cocktails contain the same reagents as primary and secondary scintillators that were used in ROTISZINT®Eco plus. Thus, neither the excitation nor the detection wavelength change for the application.
We also recommend to use the same scintillation protocol in the first approaches with one of the new ROTISZINT® cocktails as was previously used with the cocktail Eco plus (0016). In many cases, the parameters are directly transferable. If the scintillation results are not satisfactory at first, the sample quantity (the ratio sample/cocktail) can be readjusted.



ROTISZINT®Routine ROTISZINT® ready-to-use, NPE free, for scintillation

Safe and easy-to-use scintillation cocktail for a wide range of applications. ROTISZINT®Routine has a good sample uptake capacity for all aqueous samples and is suitable for solutions with high ionic strength.
Biodegradable.

  • NPE free - environmentally safe and non-carcinogenic
  • High counting efficiency
  • Low photo- and chemoluminescence
  • Very good colour- and chemical quench resistance
  • Virtually odor- and colourless
  • High flash point
  • No permeation through plastic vials

For some solvents, such as 0.3 M HNO3, the sample uptake capacity is up to 5 ml / 10 ml cocktail. For most common as well as for higher concentrated solutions (for example 0.1 M ammonium citrate, 0.1 M EDTA or 2 M HNO3) the maximum sample volume is 2 to 3.5 ml / 10 ml cocktail.


Application

Excellent for measuring solutions. For the measurement of filter samples we recommend the use of ROTISZINT®Filter.

We recommend the use of ROTILABO®Dispensers.



Technical Information
Emissions maximum 420 nm 
ROTISZINT®Routine
Selected quantity:   0
  1. Subtotal:  0.00
Art. No. Pack Qty. Pack. Price Quantity
1P1A.1 500 ml plastic

€57.95

1P1A.2 5 l plastic

€461.20

In stock
Available
In procurement
No longer available
Delivery date currently unknown
Selected quantity:   0
  1. Subtotal:  0.00

Downloads / MSDS


General information

Advantages of ROTISZINT® scinitillation cocktails

The composition of the ROTISZINT® cocktails is modern and does not contain NPE (nonylphenylethoxylates, subject to REACH). The cocktails thus comply with the Directive 2003/53/EC of the European Parliament and Council.
NPE has been replaced by a combination of several reagents specifically adapted to the respective use. The cocktails can thus be used in a targeted manner and give very high counting yields.

All new ROTISZINT® cocktails are biodegradable. Due to the low vapour pressure of the solvent, there is no odour nuisance, the solution is difficult to ignite and economical in consumption. ROTISZINT® shows excellent quench resistance, good sample stability, no chemiluminescence and no diffusion through plastic vials.

  • High counting efficiency
  • Low quenching
  • Flame retardant
  • NPE free
  • Biodegradable
  • Non carcinogenic
  • According to 2003/53/ECC


Application of modern ROTISZINT® scintillation cocktails

The ROTISZINT® scintillation cocktails of the next generation are modern, versatile, ready-to-use scintillation cocktails for liquid scintillation (LSC) of β-emitters (e.g. 3H, 14C, 32P , 35S). The ROTISZINT® scintillation cocktails are applicable for scintillation of aqueous samples in the entire biological, biochemical and chemical field.

Wide excitation range between 190 and 370 nm
emission maximum: 420-430 nm
The modern ROTISZINT® cocktails contain the same reagents as primary and secondary scintillators that were used in ROTISZINT®Eco plus. Thus, neither the excitation nor the detection wavelength change for the application.

We still recommend to use the same scintillation protocol in the first approaches with one of the new ROTISZINT® cocktails that was previously used with cocktail 0016. In many cases, the parameters are directly transferable. If the scintillation results are not satisfactory at first, the sample quantity (the ratio sample / cocktail) can be rebalanced.


Easy application by means of dispensers

ROTISZINT® Cocktails are supplied in black plastic bottles that can be used as stand-up containers. They allow safe and space-saving storage and use.
With a practical dispenser, you can conveniently and safely take out the amount of cocktail you need at any time. We recommend the use of ROTILABO®Dispensers (Art. No. HAC6.1-HAC9.1, HAE0.1 oder HAE1.1) and telescopic suction pipe (Art. No. AA92.1).
To withdraw the entire liquid, you can easily replace the inner withdrawal tube with a longer Teflon® or polyethylene tube (6 mm innerØ), or use the telescopic suction tube (order no. AA92.1).


Certificates of Analysis

You can search for and download your certificate of analysis for the selected product here. Please provide your batch number.
The following analysis certificates have been found:

Type analysis

Appearance of solutionclear, fluorescent
Odourweak, clearly noticeable
Specific weight0.96-1.0 g/ml
Background≤30 cpm
Counting efficiency≥610 tSIE
Chemoluminescence≤30 cpm
Misciblecomplies