Jump to content Jump to navigation menu

Arsenic ICP Standard Solution, 100 ml

ROTI®Star 1 000 mg/l As, in 2 % HNO3
Icon_EVE-EUD Please consider that this product might be liable to some legal sanctions as for example to obtain an end user declaration or the prohibition of some applications. For details please do contact your counterpart in our sales department!
Examples of effect: Damage metals and burn body tissues; may cause serious eye damage. Safety: Avoid contact; wear safety spectacles and gloves. In the event of contact with eyes and skin, rinse with water.
Examples of effect: Have an allergenic effect, carcinogenic, mutagenic, toxic to reproduction and cause developmental toxicity (reprotoxic) or damage to organs Safety: You must be well-informed before starting work with these substances; wear protective clothing and gloves, eye protection and mask or breathing protection.
Danger
H290-H315-H319-H350
i may be corrosive to metals, causes skin irritation, causes serious eye irritation, may cause cancer
P280
i wear protective gloves/protective clothing/eye protection/face protection
Related products
Number of elements
Concentration
Pack Qty.
Pack.
Arsenic Standards
Density (D) 1,013 g/cm³
Boiling point (bp) ~100 °C
Melting point (mp) ~0 °C
ADR 8 III
WGK 3
UN-Nr. 3264


Single Element Standards for ICP-OES
Product details

€73.65/Pack Qty. 

excl. VAT. | 100 ml per Pack Qty.

Art. No. 2399.1

In stock
Delivery fast, simple and reliable!
from 6 Pack Qty. €69.97/Pack Qty.
from 24 Pack Qty. €66.28/Pack Qty.

Product details


Single Element Standards for ICP-OES

(Inductively Coupled Plasma – Optical Emission Spectrometry)

The solutions and mixtures are made using materials of the highest purity, and therefore meet the requirements for instrumental analysis by AAS and ICP. All solutions are certified and can be traced to NIST standard reference solutions (excluded: iridium, osmium and ruthenium). Solutions are produced according to ISO 17034 in an accredited environment. The solutions are tested in a laboratory accredited to ISO/IEC 17025 and supplied with a detailed, batch-specific certificate of analysis. Each standard solution is made of high purity starting materials (mostly ≥99,999 %), and its content is determined gravimetrically and by ICP. High quality acids (purified by subboiling distillation) and water are used for production of the solutions. This gives you first-class reference materials of the highest purity and quality.

  • Up to 70 measured trace impurities in the ppt range
  • 24 months shelf life for unopened bottle & 12 months after the bottle has been opened



Arsenic ICP Standard Solution ROTI®Star 1 000 mg/l As, in 2 % HNO3

Technical Information
Number of elements
Element Arsenic (As) 
Concentration 1 000 mg/l 
Matrix 2 % HNO3 
Arsenic ICP Standard Solution
Selected quantity:   0
  1. Subtotal:  0.00
Art. No. Number of elements Concentration Pack Qty. Pack. Price Quantity
2399.1 1 1 000 mg/l 100 ml HDPE

€73.65

2399.2 1 1 000 mg/l 30 ml HDPE

€51.10

In stock
Available
In procurement
No longer available
Delivery date currently unknown
Selected quantity:   0
  1. Subtotal:  0.00

Downloads / MSDS


General information

ROTI®Star Standards for AAS and ICP

Carl ROTH has an extensive range of products which meets the highest standards of quality in the field of element standards and ion standards. The solutions and mixtures are made using materials of the highest purity, and therefore meet the requirements for instrumental analysis by AAS and ICP. All solutions are certified and can be traced to NIST standard reference materials. Solutions are produced according to ISO 17034 in an accredited environment. The solutions are tested in a laboratory accredited to ISO/IEC 17025 and supplied with a detailed, batch-specific certificate of analysis.


We are offering you our ROTI®Star multi-element standard solutions as custom-made solutions which are manufactured with your special requirement.
You will find the form for your customised solution at www.carlroth.com


Single Element Standards for ICP-OES

(Inductively Coupled Plasma – Optical Emission Spectrometry)

The solutions and mixtures are made using materials of the highest purity, and therefore meet the requirements for instrumental analysis by AAS and ICP. All solutions are certified and can be traced to NIST standard reference solutions (excluded: iridium, osmium and ruthenium). Solutions are produced according to ISO 17034 in an accredited environment. The solutions are tested in a laboratory accredited to ISO/IEC 17025 and supplied with a detailed, batch-specific certificate of analysis. Each standard solution is made of high purity starting materials (mostly ≥99,999 %), and its content is determined gravimetrically and by ICP. High quality acids (purified by subboiling distillation) and water are used for production of the solutions. This gives you first-class reference materials of the highest purity and quality.

  • Up to 70 measured trace impurities in the ppt range
  • 24 months shelf life for unopened bottle & 12 months after the bottle has been opened


Single Element Standards for ICP-MS

(Inductively Coupled Plasma - Mass spectrometry)

The solutions and mixtures are made using materials of the highest purity, and therefore meet the requirements for instrumental analysis by AAS and ICP. All solutions are certified and can be traced to NIST standard reference solutions (excluded: iridium, osmium and ruthenium). Solutions are produced according to ISO 17034 in an accredited environment. The solutions are tested in a laboratory accredited to ISO/IEC 17025 and supplied with a detailed, batch-specific certificate of analysis. Each standard solution is made of high purity starting materials (mostly ≥99,999 %), and its content is determined gravimetrically and by ICP. High quality acids (purified by subboiling distillation) and water are used for production of the solutions. This gives you first-class reference materials of the highest purity and quality.

  • Concentration: 10 mg/l and 100 mg/l
  • Up to 70 measured trace impurities in the ppt range
  • Up to 36 months shelf life on the unopened bottles


Single Element Standards for ICP-OES

(Inductively Coupled Plasma – Optical Emission Spectrometry)


Certificates of Analysis

You can search for and download your certificate of analysis for the selected product here. Please provide your batch number.
The following analysis certificates have been found:

Type analysis

c (As) as H3AsO4 in 2 % HNO31000 mg/l
Traceable to SRM from NIST.