Jump to content Jump to navigation menu

Spray solution for xanthine visualisation (caffeine, theophylline, theobromine)

for TLC
Icon_ready-to-use Ready-to-use products and reagents
Icon_EVE-EUD Please consider that this product might be liable to some legal sanctions as for example to obtain an end user declaration or the prohibition of some applications. For details please do contact your counterpart in our sales department!
Examples of effect: Flammable; liquids form compounds with the air which can become explosive; produce flammable gases with water or can self-combust. Safety: Keep away from open flames and sources of heat; close containers tightly; store in a fire-safe manner.
Examples of effect: Damage metals and burn body tissues; may cause serious eye damage. Safety: Avoid contact; wear safety spectacles and gloves. In the event of contact with eyes and skin, rinse with water.
Examples of effect: Lead to damage to heath, cause irritation to eyes, skin or respiratory organs. Are fatal in larger quantities. Safety: As previously stated, in the event of skin irritation or contact with eyes, rinse with water or a suitable medium.
Examples of effect: Have an allergenic effect, carcinogenic, mutagenic, toxic to reproduction and cause developmental toxicity (reprotoxic) or damage to organs Safety: You must be well-informed before starting work with these substances; wear protective clothing and gloves, eye protection and mask or breathing protection.
Danger
H225-H290-H315-H317-H318-H336-H373
i highly flammable liquid and vapour, may be corrosive to metals, causes skin irritation, may cause an allergic skin reaction, causes serious eye damage, may cause drowsiness or dizziness, may cause damage to organs (thyroid gland) through prolonged or repeated exposure (if swallowed)
P210 P280 P302+P352 P305+P351+P338 P333+P313
i keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking, wear protective gloves/eye protection, IF ON SKIN: Wash with plenty of water, IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing, if skin irritation or rash occurs: Get medical advice/attention
Related products
Pack Qty.
Pack.
Density (D) 0,82 g/cm³
Boiling point (bp) 56 °C
Flash point (flp) -17 °C
Storage temp. +4 °C
ADR 3 II
WGK 1
UN-Nr. 2924

Ready-to-use spray solution for detection of purine alkaloids (caffeine, theophylline, theobromine). Solution of tartaric acid, iodine and ferric chloride in acetone.

Further attractive products to complete your chromatography laboratory can be found on our Chromatography page!
Product details

€45.05/Pack Qty. 

excl. VAT. | 100 ml per Pack Qty.

Art. No. 1H07.1

In stock
Delivery fast, simple and reliable!
from 6 Pack Qty. €42.80/Pack Qty.
from 24 Pack Qty. €40.54/Pack Qty.

Product details


Further attractive products to complete your chromatography laboratory can be found on our Chromatography page!



Spray solution for xanthine visualisation (caffeine, theophylline, theobromine) for TLC

Spray solution for xanthine visualisation (caffeine, theophylline, theobromine)
Selected quantity:   0
  1. Subtotal:  0.00
Art. No. Pack Qty. Pack. Price Quantity
1H07.1 100 ml glass

€45.05

In stock
Available
In procurement
No longer available
Delivery date currently unknown
Selected quantity:   0
  1. Subtotal:  0.00

Downloads / MSDS


General information

Further attractive products to complete your chromatography laboratory can be found on our Chromatography page!


Thin Layer Chromatography (TLC)

Although the principle of thin-layer chromatography is more than a century old, it did not make its breakthrough as an analytical method until about 50 years ago.
Thanks to the development of new sorbents and supports, as well as increasing instrumentation and automation, TLC has become a versatile separation method. It is used both in qualitative analysis and in quantitative analysis.
Applications range from simple manual separation processes in classic TLC to automated processes in HPTLC (high performance thin layer chromatography).

Advantages of thin layer chromatography:

  • Higher sample throughput in less time
  • Suitable for screening tests
  • Pilot process for HPLC
  • The ready-to-use TLC layer functions as a data storage device for separation results
  • The separated substances can be used later for further analysis (e.g. IR, MS)
  • By switching the mobile and the stationary phases, the separation process can be optimised quickly and cost-efficient


Spray solutions

Carl ROTH’s ready-to-use spray solutions make thin-layer chromatography operations considerably easier.
For these ready-to-use spray solutions the staining/derivative reagent was dissolved in ethanol, 2-propanol or in water.


Certificates of Analysis

You can search for and download your certificate of analysis for the selected product here. Please provide your batch number.
The following analysis certificates have been found:

Type analysis

TLC-applicationcomplies