Naar de inhoud springen Naar het navigatiemenu springen

ROTI®Load DNA-tricolor (with glycerol)

6x conc., DNase-free
Icon_ready-to-use Ready-to-use products and reagents
Icon_DNAse-free
Verwante producten
VE
Verp.
Verpakking
Density (D) 1 g/cm³
Storage temp. -20 °C
Transport temp. ambient temp.
WGK 1

DNA-gel loading buffer for DNA gel electrophoresis, suitable for a broad range of fragments.
Contains: Tris, Na-acetate, EDTA, bromophenol blue, xylene cyanol, orange G and glycerol

68,30 €/VE 

Excl. btw | 9 ml Per VE

Bestelnr. HP06.1

Op voorraad
Vrij van verzendingskosten vanaf 250 €
Snelle en betrouwbare levering!
Vanaf 6 VE 64,88 €/VE
Vanaf 24 VE 61,47 €/VE

Productdetails



ROTI®Load DNA-tricolor (with glycerol) 6x conc., DNase-free

Technische informatie
Kleurstof Bromphenol blue, Xylene cyanole, Orange G 
Incl. DNA-kleuring nee 
Toepassing Broad size range, high flexibility 
ROTI®Load DNA-tricolor (with glycerol)
Geselecteerde hoeveelheid:   0
  1. Tussentotaal:  0.00
Bestelnr. VE Verp. Verpakking Prijs Hoeveelheid
HP06.1 9 ml plastic 5 x 1,8 ml

68,30 €

Op voorraad
Beschikbaar
In bestelling
Niet meer verkrijgbaar
Leveringsdatum onbekend
Geselecteerde hoeveelheid:   0
  1. Tussentotaal:  0.00

Downloads / MSDS


Algemene informatie

Selecting a Suitable ROTI®Load Gel Loading Buffer for Nucleic Acids

Care should be taken to ensure that the dyes contained in the gel stop before smallest relevant DNA bands. This ensures that the buffer can be stopped in time. However, the selected dyes may overlay the bands shown. In this case, select a loading buffer that does not contain any unwanted dyes.
Bromophenol blue and xylene cyanol can be used as colour markers in all standard gels. If a relevant band is overlaid by one of these colour markers, choose a gel loading buffer containing Orange G. If small fragments are to be assayed, the gel loading buffer should contain Orange G in order to mark the run. If relevant bands are overlaid, however, a choice can be made between bromophenol blue or xylene cyanol depending on the size of the bands. A loading buffer without xylene cyanol is usually used for assaying large fragments.

Glycerine is the standard reagent for increasing the density of samples.
Ficoll® 400 produces particularly well-defined bands.


Analysecertificaten

Hier kunt u uw analysecertificaat voor het geselecteerde product zoeken en downloaden. Geef een chargenummer op.
De volgende analysecertificaten werden gevonden:

Notes on the product

Each batch is functionally tested for its suitability in electrophoresis and for DNAse-freeness.