product.details.print
HPLC column NUCLEODUR® 100-5 C18 ec 5 µm, 250 mm, 4.6 mm
488,05 €/VE
Excl. btw | 1 stuks Per VE
Bestelnr. KK85.1
Productdetails
The ideal phase for routine HPLC analysis.
- Octadecyl phase, endcapped
- Carbon content: 17.5 %
- Pore size: 110 Å
- pH stability: 1-9
- Eluent on column: acetonitrile/water
Eluent: acetonitril/water (75/25, v/v); Flow: 1,3 ml/min; Temperature: 30 °C; Detection: UV, 254 nm
Legend:
1. Toluene, 2. Ethylbenzene, 3. Propylbenzene, 4. Butylbenzene, 5. Pentylbenzene
Similar phases:
For many applicatons the following phases can be replaced with identical or even better results: NUCLEOSIL® C18, Spherisorb® ODS I und II, Hypersil™ ODS, Waters Symmetry®C18, Inertsil® ODS II, Kromasil® C18, LiChrospher® RP18 und RP C18 ec.
U vindt nog meer aantrekkelijke aanbiedingen om uw chromatografielaboratorium te vervolledigen op onze Chromatografie pagina!
For protection of your main HPLC column from contamination, it is recommended to use guard columns. These short columns are placed into a guard column holder. The guard column holder in combination with a guard column inside is installed between the injector and the HPLC column. This installation prevents chemical impurities to reach the main column. Because a contamination could form an irreversible bond with the column packing material (stationary phase) and this can result in shorter column life. If you want to prolong the lifetime of your main column, then these short columns can help you.
Further HPLC columns from Macherey-Nagel available on request.
Non-polar phases for routine analysis
Standard RP phase (110 Å) for daily routine analysis and up-scaling to preparative HPLC. Also available wide-pore (300 Å) for separation of biomolecules in analytical columns.
Eigenschappen:
- Cost-effective and reliable
- Long-life columns
- For all standard routine applications in modern RP-chromatography
Aanbevolen toepassingen:
- Pore size 100 Å:
Basic, neutral and acidic pharmaceuticals, derivatised amino acids, pesticides, fat-soluble vitamins, aldehydes and ketones, phenolic compounds. - Pore size 300 Å:
Biological macromolecules, such as proteins or peptides. - USP L1 (C18) · USP L7 (C8) · USP L26 (C4)
HPLC column NUCLEODUR® 100-5 C18 ec 5 µm
Partikel grootte | 5 µm |
Zuillengte | 250 mm |
Kolom binnendiameter | 4.6 mm |
Kolomvolume | 4.15 ml |
Endcapped | ja |
Eluent in kolom | Acetonitrile - Water |
Fase | 100-5 C18 ec |
Surface chemistry | Medium density monomeric octadecyl (C18, ODS) modification |
USP lijst | L1 |
Scheidingsprincipe | Reversed phase (RP) |
Zuilvorm | Analytical separation column |
Zuiltype | HPLC column |
Partikel soort | Fully porous particles (FPP) |
Specifiek oppervlak volgens BET | 340 m²/g |
Poriënvolume | 0.9 ml/g |
Poriëngr. | 110 Å |
Temperatuurstabiliteit | 60 °C |
Drukstabiliteit | 600 bar |
pH-stabiliteit | 1,0-9,0 |
Aanbevolen toepassing(en) | Aldehydes, Basic, neutral or acidic drugs, Derivatized amino acids, Fat-soluble vitamins, Ketones, Pesticides, Phenolic compounds |
Vergelijkbare fasen |
NUCLEOSIL® C18 Spherisorb® ODS I Spherisorb® ODS II Hypersil™ ODS Symmetry® C18 Inertsil® ODS II Kromasil® C18 LiChrospher® RP18 LiChrospher® RP C18 ec |
- Tussentotaal: 0.00
Bestelnr. | Partikel grootte | Zuillengte | Kolom binnendiameter | VE | Prijs | Hoeveelheid | |
---|---|---|---|---|---|---|---|
KK85.1 | 5 µm | 250 mm | 4,6 mm | 1 stuks |
488,05 € |
|
|
KK84.1 | 5 µm | 150 mm | 4,6 mm | 1 stuks |
401,00 € |
|
|
KK83.1 | 5 µm | 250 mm | 4 mm | 1 stuks |
462,25 € |
|
|
Op voorraad
Beschikbaar
In bestelling
Niet meer verkrijgbaar
Leveringsdatum onbekend
|
- Tussentotaal: 0.00
Downloads / MSDS
Algemene informatie
U vindt nog meer aantrekkelijke aanbiedingen om uw chromatografielaboratorium te vervolledigen op onze Chromatografie pagina!
NUCLEODUR® as a state-of-the-art silica is the ideal base material for modern HPLC phases. We offer two phases NUCLEODUR® Gravity which is ideal for sophisticated analytical separations and NUCLEODUR® ec suitable for routine HPLC analysis.