product.details.print
Petroleum ether 40-60 °C, 1 l
Boiling point (bp) 60 °C
Flash point (flp) -40 °C
ADR 3 II
WGK 2
UN-Nr. 3295
50,00 €/VE
Excl. btw | 1 l Per VE
Bestelnr. T170.2
Productdetails
Petroleum ether 40-60 °C ROTISOLV® Pestilyse®
Watermengbaarheid | no |
- Tussentotaal: 0.00
Bestelnr. | VE | Verp. | Prijs | Hoeveelheid | |
---|---|---|---|---|---|
T170.1 | 2,5 l | glass |
98,80 € |
|
|
T170.2 | 1 l | glass |
50,00 € |
|
|
T170.3 | 4 l | glass |
139,25 € |
|
|
Op voorraad
Beschikbaar (let op levertijd)
In bestelling
Niet meer verkrijgbaar
Leveringsdatum onbekend
|
- Tussentotaal: 0.00
Downloads / MSDS
Algemene informatie
U vindt nog meer aantrekkelijke aanbiedingen om uw chromatografielaboratorium te vervolledigen op onze Chromatografie pagina!
The hydrocarbon index is defined as the total of all organic substances that can be extracted with hexane, but cannot be adsorbed in Florisil® (magnesium silicate). On a covalent GC column, these elute between n-decane and n-tetracontane and have a boiling range of 175-525 °C. These include heating oils, diesel fuels, kerosene, lubricants and transmission fluids. Petrols are not detected using this method. Carl ROTH offers an extensive range of products for the determination of the hydrocarbon index in accordance with EN ISO 9377-2-Mod. (DIN H53).
Standards
According to EN ISO 9377-2-Mod. (DIN H53)
- Manufactured in accordance with ISO 17034 in an accredited environment
- Tested in a laboratory accredited to ISO/IEC 17025
- Ideal for calibration of GC-FID, GC-TCD, GC-ECD, GC-MS, GC-MS/MS, LC-UV, LC-MS and LC-MS/MS
- With an detailed, batch-related certificate of analysis
for residue and environmental analysis
Field of application: ‘Pesticide Residue Analysis’ (via ECD, PND detection) in sectors environment, foodstuff, water, etc. ROTISOLV® Pestilyse® solvents are ideal as extraction agents and for sample preparation.
Eigenschappen:
- Highest purity
- Quality control via ECD and PND
- Non-volatile parts: 5 ppm or less
- Specially purified for application in pesticide residue analysis
Analysecertificaten
Guarantee analysis
Boiling range | 40-60 °C |
Water (KF) | ≤0,02 % |
Acidity | ≤0,0005 meq/g |
Evaporation residue | ≤0,0001 % |
GC/ECD (individual signal as lindane) | ≤5 ng/l |