Naar de inhoud springen Naar het navigatiemenu springen

Sodium sulphite, 2.5 kg

≥98 %, p.a., ACS, anhydrous
VE
Verp.
Empirical formula Na2SO3
Molar mass (M) 126,04 g/mol
Density (D) 2,63 g/cm³
Melting point (mp) 911 °C
WGK 1
CAS No. 7757-83-7
EG-Nr. 231-821-4

For removal of chlorine and dissolution of cellulose, reagent for detection of iodate in the presence of chlorate and bromate, for absorption of NOx in gas analysis.

66,55 €/VE 

Excl. btw | 2,5 kg Per VE

Bestelnr. P033.3

Op voorraad
Vrij van verzendingskosten vanaf 250 €
Snelle en betrouwbare levering!
Vanaf 6 VE 63,22 €/VE
Vanaf 24 VE 59,90 €/VE
Sodium sulphite
Geselecteerde hoeveelheid:   0
  1. Tussentotaal:  0.00
Bestelnr. VE Verp. Prijs Hoeveelheid
P033.1 500 g plastic

23,15 €

P033.2 1 kg plastic

36,45 €

P033.3 2,5 kg plastic

66,55 €

Op voorraad
Beschikbaar
In bestelling
Niet meer verkrijgbaar
Leveringsdatum onbekend
Geselecteerde hoeveelheid:   0
  1. Tussentotaal:  0.00

Downloads / MSDS


Algemene informatie

Indicators and Dyes

Carl ROTH offers many indicators and dyes of high purity, which can be used in special applications.


Salts for Analysis

Our salts for analysis are manufactured under strict production guidelines. Analytical purity and best quality reliably characterize each batch. Salts in p.a. quality made by Carl ROTH meet the high requirements for reproducible results. Most of our salts are additionally specified according to international standards like ACS and ISO.

Definition:
p.a.: pro analysi (for analysis)ACS: American Chemical SocietyISO: International Standard Organisation


Salts


Determination of adsorbable organic halogen compounds (AOX)

AOX (adsorbable organic halogens, where X = Cl, Br, I) is a sum parameter that describes the amount of organic halogen compounds in substances such as water, soil and sewage sludge. This parameter is used primarily in waste water analysis. The method for calculating AOX levels is set out in DIN EN ISO 9562. The quantity of organically bound halogens in a water sample is measured using either the shaking method or the column method. In the shaking method, the AOX in a sample are bound to activated carbon by shaking. In the column method, the AOX in a sample are bound to activated carbon by the action of flushing the sample through a glass column filled with activated carbon. The quantity of activated carbon, which is defined precisely in each case, is then burned in an oxygen chamber and the hydrogen halide released is measured by means of argentometry. The amount of fluoroorganic compounds present cannot be measured argentometrically.


Analysecertificaten

Hier kunt u uw analysecertificaat voor het geselecteerde product zoeken en downloaden. Geef een chargenummer op.
De volgende analysecertificaten werden gevonden:

Guarantee analysis

Assay (iodom.)≥98.0 %
In H2O insoluble matter≤0.005 %
Aciditycomplies
Alkalinity≤0.03 meq/g
Thiosulphatecomplies
Chloride (Cl)≤0.02 %
Arsenic (As)≤0.0001 %
Lead (Pb)≤0.001 %
Calcium (Ca)≤0.013 %
Iron (Fe)≤0.001 %
Potassium (K)≤0.05 %
Copper (Cu)≤0.001 %
Magnesium (Mg)≤0.013 %
Nickel (Ni)≤0.001 %
Heavy Metals (ICP-OES)≤0.001 %