Naar de inhoud springen Naar het navigatiemenu springen

HPLC Guard Columns (analytical) NUCLEODUR® NH2-RP 3 µm, 4x3 mm

Van  Macherey-Nagel
Verwante producten
L x Ø binnen (kolom)


For protection of your main HPLC column from contamination, it is recommended to use guard columns. These short columns are placed into a guard column holder. The guard column holder in combination with a guard column inside is installed between the injector and the HPLC column. This installation prevents chemical impurities to reach the main column. Because a contamination could form an irreversible bond with the column packing material (stationary phase) and this can result in shorter column life. If you want to prolong the lifetime of your main column, then these short columns can help you.
Productdetails

156,95 €/VE 

Excl. btw | 3 stuks Per VE

Bestelnr. 1NE5.1

Beschikbaar
Vrij van verzendingskosten vanaf 250 €
Klaar voor verzending in 3-4 weken
Vanaf 6 VE 149,10 €/VE
Vanaf 24 VE 141,26 €/VE

Productdetails


For protection of your main HPLC column from contamination, it is recommended to use guard columns. These short columns are placed into a guard column holder. The guard column holder in combination with a guard column inside is installed between the injector and the HPLC column. This installation prevents chemical impurities to reach the main column. Because a contamination could form an irreversible bond with the column packing material (stationary phase) and this can result in shorter column life. If you want to prolong the lifetime of your main column, then these short columns can help you.


U vindt nog meer aantrekkelijke aanbiedingen om uw chromatografielaboratorium te vervolledigen op onze Chromatografie pagina!



HPLC Guard Columns (analytical) NUCLEODUR® NH2-RP 3 µm, 4x3 mm 

Technische informatie
Kolom binnendiameter 3 mm
Zuillengte 4 mm
L x Ø binnen (kolom) 4 x 3 mm
Endcapped ja 
Eluent in kolom Acetonitrile - Water 
Surface chemistry Aminopropyl (NH2) modification 
Scheidingsprincipe Multi-mode (RP and NP), Reversed phase (RP) 
Partikel soort Fully porous particles (FPP) 
Partikel grootte 3 µm
Specifiek oppervlak volgens BET 340 m²/g
Poriënvolume 0.9 ml/g
Poriëngr. 110 Å
Temperatuurstabiliteit 60 ° C 
Drukstabiliteit 400 bar 
pH-stabiliteit 1.0 - 11.0 
Koolstofgehalte 11 %
HPLC Guard Columns (analytical) NUCLEODUR® NH2-RP 3 µm, 4x3 mm
Geselecteerde hoeveelheid:   0
  1. Tussentotaal:  0.00
Bestelnr. L x Ø binnen (kolom) VE Prijs Hoeveelheid
1NE5.1 4 x 3 mm 3 stuks

156,95 €

Op voorraad
Beschikbaar
In bestelling
Niet meer verkrijgbaar
Leveringsdatum onbekend
Geselecteerde hoeveelheid:   0
  1. Tussentotaal:  0.00

Downloads / MSDS

Geen documenten beschikbaar

Algemene informatie

U vindt nog meer aantrekkelijke aanbiedingen om uw chromatografielaboratorium te vervolledigen op onze Chromatografie pagina!