(+)-Borneol

ROTICHROM® GC
Mogelijke gevolgen: zijn ontvlambaar; vloeistoffen vormen met lucht explosieve mengsels; zorgen met water voor ontvlambare gassen of zijn zelfontvlambaar. Veiligheid: uit de buurt van open vuur en warmtebronnen houden; vaten dicht afsluiten; brandveilig bewaren.
Warning
H228
i flammable solid
P210 P280
i keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking, wear protective gloves/eye protection
VE
Verp.
(+)-Bornyl alcohol
Empirical formula C10H18O
Molar mass (M) 154,25 g/mol
Flash point (flp) 65 °C
Melting point (mp) 206 °C
Storage temp. +4 °C
ADR 4.1 III
WGK 1
CAS No. [464-43-7]
EG-Nr. 207-352-6
UN-Nr. 1312

Reference substance for GC.

Type analysis

148,90 €/VE 

Excl. btw | 100 mg Per VE

Bestelnr. 8903.1

Binnenkort beschikbaar
Vrij van verzendingskosten vanaf 125 €
Vanaf 6 VE 141,46 €/VE
Vanaf 24 VE 134,01 €/VE
Carl Roth abonnementservice

Now recurring orders conveniently delivered as a subscription!

With the new Carl Roth Replenishment Service you can let products be ordered automatically which you need regularly in your lab!

How it works:
1

Put all products for your subscription in the desired quantity in the basket.

2

In the shopping cart, select the option "Order shopping cart as subscription" Order as subscription.

3

Set Starty point and interval for your subscription and submit order!

By the way: Through your account you can customize or delete your subscriptions anytime.

Vragen over dit product?

Do you have a question about this product?

In the general information or Product details, we have compiled extensive descriptions and downloads for each product.
If you can not find an answer to your question in the Certificates of Analysis and Application Examples , feel free to contact us!
Neem contact op met service
(+)-Borneol
Geselecteerde hoeveelheid:   0
  1. Tussentotaal:  0.00
Bestelnr. VE Verp. Prijs Hoeveelheid
8903.1 100 mg plastic 148,90 €
Op voorraad
Binnenkort beschikbaar
Niet beschikbaar
Leveringsdatum onbekend op dit moment
Geselecteerde hoeveelheid:   0
  1. Tussentotaal:  0.00

Downloads

Algemene informatie

Reference Substances ROTICHROM® HPLC/TLC/GC

for Chromatography

Pure reference substances are essential for precise analysis. They are used for identifying compounds by retention time, for calibrating detectors, and for eliminating errors in quantification of the sample compounds.

Peak areas are proportional to sample quantity in all chromatographic methods. For precise quantitative analysis, however, it is necessary to calibrate the detector as the signal may significantly vary with different substances.

To avoid errors during sample preparation and injection, an internal standard should be used in any case. The standard must not be present in the sample, however, its chemical and physical properties ought to be the closest possible to the analytical targets. It must be well resolved in the chromatogram within the same range of retention time as the sample. Before sample analysis, a given volume of standard is added, and all clean‑up procedures are made with the sample containing the standard. Quantitative errors may be compensated by comparing the peak‑areas of the sample with that of the internal standard.

Reference Substances for GC

ROTICHROM® GC

Carl ROTH offers an extensive range of reference substances for gaschromatography from the substance groups of alkanes, alcohols, ketones, esters, aromatic compounds, and much more. Their GC purity allows an accurate analysis.

The ROTICHROM® GC substances come with a certificate of analysis and a GC chromatogram enclosed in the outer packaging.

Reference Substances ROTICHROM® HPLC/TLC/GC

for Chromatography

Pure reference substances are essential for precise analysis. They are used for identifying compounds by retention time, for calibrating detectors, and for eliminating errors in quantification of the sample compounds.

Peak areas are proportional to sample quantity in all chromatographic methods. For precise quantitative analysis, however, it is necessary to calibrate the detector as the signal may significantly vary with different substances.

To avoid errors during sample preparation and injection, an internal standard should be used in any case. The standard must not be present in the sample, however, its chemical and physical properties ought to be the closest possible to the analytical targets. It must be well resolved in the chromatogram within the same range of retention time as the sample. Before sample analysis, a given volume of standard is added, and all clean‑up procedures are made with the sample containing the standard. Quantitative errors may be compensated by comparing the peak‑areas of the sample with that of the internal standard.

Reference Substances for GC

ROTICHROM® GC

Carl ROTH offers an extensive range of reference substances for gaschromatography from the substance groups of alkanes, alcohols, ketones, esters, aromatic compounds, and much more. Their GC purity allows an accurate analysis.

The ROTICHROM® GC substances come with a certificate of analysis and a GC chromatogram enclosed in the outer packaging.