product.details.print
n-Heptane
ROTISOLV® Pestilyse® ≥99 %
H225-H304-H315-H336-H410
highly flammable liquid and vapour, may be fatal if swallowed and enters airways, causes skin irritation, may cause drowsiness or dizziness, very toxic to aquatic life with long lasting effects
P210 P273 P301+P310 P304+P340 P331 P403+P235
keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking, avoid release to the environment, IF SWALLOWED: Immediately call a POISON CENTER/doctor, IF INHALED: Remove person to fresh air and keep comfortable for breathing, do NOT induce vomiting, store in a well-ventilated place. Keep cool
Verwante producten
VE
Verp.
Methyl hexane, 1-Methyl hexane
Empirical formula C7H16
Molar mass (M) 100,20 g/mol
Density (D) 0,69 g/cm³
Boiling point (bp) 98,4 °C
Flash point (flp) -4 °C
Melting point (mp) -90,5 °C
ADR 3 II
WGK 2
CAS No. 142-82-5
EG-Nr. 205-563-8
UN-Nr. 1206
Molar mass (M) 100,20 g/mol
Density (D) 0,69 g/cm³
Boiling point (bp) 98,4 °C
Flash point (flp) -4 °C
Melting point (mp) -90,5 °C
ADR 3 II
WGK 2
CAS No. 142-82-5
EG-Nr. 205-563-8
UN-Nr. 1206
For residue and environmental analysis.
134,40 €/VE
Excl. btw | 2,5 l Per VE
Bestelnr. X878.1
Op voorraad
Vrij van verzendingskosten vanaf 250 €
Snelle en betrouwbare levering!
Vanaf 4 VE
127,68 €/VE
Vanaf 24 VE
120,96 €/VE
In het winkelmandje
Productdetails
n-Heptane ROTISOLV® Pestilyse® ≥99 %
Technische informatie
Watermengbaarheid | no |
In het winkelmandje
n-Heptane
Geselecteerde hoeveelheid:
0
- Tussentotaal: 0.00
In het winkelmandje
Bestelnr. | VE | Verp. | Prijs | Hoeveelheid | |
---|---|---|---|---|---|
X878.1 | 2,5 l | glass |
134,40 € |
|
|
Op voorraad
Beschikbaar
In bestelling
Niet meer verkrijgbaar
Leveringsdatum onbekend
|
Geselecteerde hoeveelheid:
0
- Tussentotaal: 0.00
In het winkelmandje
Downloads / MSDS
Algemene informatie
U vindt nog meer aantrekkelijke aanbiedingen om uw chromatografielaboratorium te vervolledigen op onze Chromatografie pagina!
ROTISOLV® Pestilyse® Solvents
for residue and environmental analysis
Field of application: ‘Pesticide Residue Analysis’ (via ECD, PND detection) in sectors environment, foodstuff, water, etc. ROTISOLV® Pestilyse® solvents are ideal as extraction agents and for sample preparation.
Eigenschappen:
- Highest purity
- Quality control via ECD and PND
- Non-volatile parts: 5 ppm or less
- Specially purified for application in pesticide residue analysis
Analysecertificaten
Guarantee analysis
Assay (GC) | ≥99 % |
Water (KF) | ≤0,005 % |
Acidity | ≤0,0005 meg/g |
Evaporation residue | ≤0,0005 % |
GC/ECD (individual signal as lindan) | ≤ 5 ng/l |
GC/PND (individual signal as ethylparathion) | ≤10 ng/l |