Naar de inhoud springen Naar het navigatiemenu springen

MM Separator PCR Strip Adapter, uncoated

Van  magtivio
Icon_Made-in-Germany Goods manufactured in Germany
Uitvoering


Made from acrylic glas for optimal visual inspection needs, and from chemically resistant polyoxymethylene (POM) (versions “P”) for routine use of organic solvents.
Productdetails

282,75 €/VE 

Excl. btw | 1 stuks Per VE

Bestelnr. 2155.1

In bestelling
Vrij van verzendingskosten vanaf 250 €
Vanaf 6 VE 268,61 €/VE
Vanaf 24 VE 254,48 €/VE

Productdetails


Made from acrylic glas for optimal visual inspection needs, and from chemically resistant polyoxymethylene (POM) (versions “P”) for routine use of organic solvents.


Toepassingsvoorbeelden

MM-Separators are designed for optimal magnetic bead separation in terms of speed and bead pellet positioning, as well as stability and user-friendliness.


magtivio’s MM-Separators are intended for magnetic separation of MagSi beads from liquid samples for isolation and purification of nucleic acids and proteins, immunoprecipitation, immunoassays (ELISA), cell sorting, and purification of biomolecules.



MM Separator PCR Strip Adapter 
Gebruiksinstructies

The PCR Strip Adapters have to be placed onto the MM-Separators M96 and are suitable for users with smaller sample throughputs, preferring use of PCR tube strips over PCR plates. These separators are suitable for use with U- or V-shaped 96 well microplates and for 96- well PCR plates in various formats, and 8- and 12-tube PCR strips.

Application area: manual use with 8- and 12-tube PCR strips, complementary to MM-Separators M96.

Compatible with 8- or 12-channel multi-pipettes.



Technische informatie
Type PCR Strip Adapter 
Aantal monsters max. 96 
L x B x H 12.8 x 8.6 x 1.0 cm
Gewicht 0,1 kg
MM Separator PCR Strip Adapter
Geselecteerde hoeveelheid:   0
  1. Tussentotaal:  0.00
Bestelnr. Uitvoering VE Prijs Hoeveelheid
2155.1 uncoated 1 stuks

282,75 €

2157.1 P version 1 stuks

282,75 €

Op voorraad
Beschikbaar
In bestelling
Niet meer verkrijgbaar
Leveringsdatum onbekend
Geselecteerde hoeveelheid:   0
  1. Tussentotaal:  0.00

Downloads / MSDS

Algemene informatie

Specific Application of Silica- and of Carboxylated Beads

Bead surface Silica beads Carboxylated beads
Compatible Buffer Systems Chaotropic buffers PEG-based, low pH or chaotropic buffers
Binding Mechanism Precipitation with chaotropic salts Precipitation by polymers like PEG, divalent cations (e.g. Mg2+) or chaotropic salts
Elution Low salt conditions Low salt conditions or pH shift from acidic to alkalineconditions
Recommended use Recommended in case chaotropic conditions can be applied. Recommended if flexibility in buffer systems is necessary or if non-chaotropic conditions have to be applied. Results in higher purity and recovery rate under non-chaotropic conditions.