Mogelijke gevolgen: vernietigen metalen en zijn bijtend voor lichaamsweefsel; ernstig oogletsel is mogelijk.
Veiligheid: contact vermijden; veiligheidsbril en handschoenen dragen. Bij contact ogen en huid met water spoelen.
Mogelijke gevolgen: leiden tot schade aan de gezondheid, irriteren organen, huid of luchtwegen. Leiden in grotere hoeveelheden tot de dood.
Veiligheid: zoals hierboven; bij huidirritaties of oogcontact met water of geschikt middel spoelen.
Danger
H314-H335-H412
icauses severe skin burns and eye damage, may cause respiratory irritation, harmful to aquatic life with long lasting effects
The solutions and mixtures are made using materials of the highest purity, and therefore meet the requirements for instrumental analysis by AAS and ICP. All solutions are certified and can be traced to NIST standard reference solutions (excluded: iridium, osmium and ruthenium). Solutions are produced according to ISO 17034 in an accredited environment. The solutions are tested in a laboratory accredited to ISO/IEC 17025 and supplied with a detailed, batch-specific certificate of analysis. Each standard solution is made of high purity starting materials (mostly ≥99,999 %), and its content is determined gravimetrically and by ICP. High quality acids (purified by subboiling distillation) and water are used for production of the solutions. This gives you first-class reference materials of the highest purity and quality.
Up to 70 measured trace impurities in the ppt range
24 months shelf life for unopened bottle & 12 months after the bottle has been opened
Tungsten ICP Standard Solution ROTI®Star 10 000 mg/l W, in 4-10 % NH3
Carl ROTH has an extensive range of products which meets the highest standards of quality in the field of element standards and ion standards. The solutions and mixtures are made using materials of the highest purity, and therefore meet the requirements for instrumental analysis by AAS and ICP. All solutions are certified and can be traced to NIST standard reference materials. Solutions are produced according to ISO 17034 in an accredited environment. The solutions are tested in a laboratory accredited to ISO/IEC 17025 and supplied with a detailed, batch-specific certificate of analysis.
We are offering you our ROTI®Star multi-element standard solutions as custom-made solutions which are manufactured with your special requirement. You will find the form for your customised solution at www.carlroth.com
The solutions and mixtures are made using materials of the highest purity, and therefore meet the requirements for instrumental analysis by AAS and ICP. All solutions are certified and can be traced to NIST standard reference solutions (excluded: iridium, osmium and ruthenium). Solutions are produced according to ISO 17034 in an accredited environment. The solutions are tested in a laboratory accredited to ISO/IEC 17025 and supplied with a detailed, batch-specific certificate of analysis. Each standard solution is made of high purity starting materials (mostly ≥99,999 %), and its content is determined gravimetrically and by ICP. High quality acids (purified by subboiling distillation) and water are used for production of the solutions. This gives you first-class reference materials of the highest purity and quality.
Up to 70 measured trace impurities in the ppt range
24 months shelf life for unopened bottle & 12 months after the bottle has been opened
Single Element Standards for ICP-MS
(Inductively Coupled Plasma - Mass spectrometry)
The solutions and mixtures are made using materials of the highest purity, and therefore meet the requirements for instrumental analysis by AAS and ICP. All solutions are certified and can be traced to NIST standard reference solutions (excluded: iridium, osmium and ruthenium). Solutions are produced according to ISO 17034 in an accredited environment. The solutions are tested in a laboratory accredited to ISO/IEC 17025 and supplied with a detailed, batch-specific certificate of analysis. Each standard solution is made of high purity starting materials (mostly ≥99,999 %), and its content is determined gravimetrically and by ICP. High quality acids (purified by subboiling distillation) and water are used for production of the solutions. This gives you first-class reference materials of the highest purity and quality.
Concentration: 10 mg/l and 100 mg/l
Up to 70 measured trace impurities in the ppt range
Up to 36 months shelf life on the unopened bottles