Naar de inhoud springen Naar het navigatiemenu springen

Hydrochloric acid

0,01 mol/l - 0,01 N, volumetric standard solution
Verwante producten
VE
Verp.
HCl, Hydrogen chloride
Empirical formula HCl
Molar mass (M) 36,46 g/mol
Density (D) 1 g/cm³
Boiling point (bp) 100 °C
Melting point (mp) ~0 °C
WGK 1
CAS No. 7647-01-0
EG-Nr. 231-595-7


25,70 €/VE 

Excl. btw | 1 l Per VE

Bestelnr. N075.1

Op voorraad
Vrij van verzendingskosten vanaf 250 €
Snelle en betrouwbare levering!
Vanaf 6 VE 24,42 €/VE
Vanaf 24 VE 23,13 €/VE
Hydrochloric acid
Geselecteerde hoeveelheid:   0
  1. Tussentotaal:  0.00
Bestelnr. VE Verp. Prijs Hoeveelheid
N075.1 1 l plastic

25,70 €

Op voorraad
Beschikbaar
In bestelling
Niet meer verkrijgbaar
Leveringsdatum onbekend
Geselecteerde hoeveelheid:   0
  1. Tussentotaal:  0.00

Downloads / MSDS


Algemene informatie

Volumetric Standard Solutions

A volumetric standard solution is a solution containing a precisely known concentration of a substance. The concentration of a volumetric standard solution is determined using a primary standard, which is accurately weighed and dissolved to make a specific volume. Volumetric standard solutions are made using reagent-grade (p.a.) substances as source materials.


Volumetric Standard Solutions, ready-to-use

The advantages of this over making them yourself are:

  • Manufactured and tested using modern manufacturing and analytical methods
  • Ready-to-use solutions
  • High accuracy for precise analyses
  • Application of NIST-certified reference substances for checking
  • Connection to standard titrators is possible


Determination of adsorbable organic halogen compounds (AOX)

AOX (adsorbable organic halogens, where X = Cl, Br, I) is a sum parameter that describes the amount of organic halogen compounds in substances such as water, soil and sewage sludge. This parameter is used primarily in waste water analysis. The method for calculating AOX levels is set out in DIN EN ISO 9562. The quantity of organically bound halogens in a water sample is measured using either the shaking method or the column method. In the shaking method, the AOX in a sample are bound to activated carbon by shaking. In the column method, the AOX in a sample are bound to activated carbon by the action of flushing the sample through a glass column filled with activated carbon. The quantity of activated carbon, which is defined precisely in each case, is then burned in an oxygen chamber and the hydrogen halide released is measured by means of argentometry. The amount of fluoroorganic compounds present cannot be measured argentometrically.


Analysecertificaten

Hier kunt u uw analysecertificaat voor het geselecteerde product zoeken en downloaden. Geef een chargenummer op.
De volgende analysecertificaten werden gevonden:

Type analysis

Amount-of-substance conc. (20 °C)0,01 mol/l ±0,5 %
Titer0,9950 - 1,0050