Jump to content Jump to navigation menu

ROTI®Phenol, 500 ml

ready-to-use, for the extraction of nucleic acids
Icon_ready-to-use Ready-to-use products and reagents
Examples of effect: Damage metals and burn body tissues; may cause serious eye damage. Safety: Avoid contact; wear safety spectacles and gloves. In the event of contact with eyes and skin, rinse with water.
Examples of effect: Lead to damage to heath, cause irritation to eyes, skin or respiratory organs. Are fatal in larger quantities. Safety: As previously stated, in the event of skin irritation or contact with eyes, rinse with water or a suitable medium.
Examples of effect: Have an allergenic effect, carcinogenic, mutagenic, toxic to reproduction and cause developmental toxicity (reprotoxic) or damage to organs Safety: You must be well-informed before starting work with these substances; wear protective clothing and gloves, eye protection and mask or breathing protection.
Danger
H290-H302+H332-H314-H341-H373-H412
i may be corrosive to metals, harmful if swallowed or if inhaled, causes severe skin burns and eye damage, suspected of causing genetic defects, may cause damage to organs through prolonged or repeated exposure, harmful to aquatic life with long lasting effects
P270 P280 P302+P352 P304+P340 P305+P351+P338 P310
i do not eat, drink or smoke when using this product, wear protective gloves/eye protection, IF ON SKIN: Wash with plenty of water, IF INHALED: Remove person to fresh air and keep comfortable for breathing, IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing, immediately call a POISON CENTER/doctor
Pack Qty.
Pack.
Phenol solutions, ROTI®Aqua-Phenol
Density (D) 1,03 g/cm³
Flash point (flp) 79 °C
Storage temp. +4 °C
ADR 6.1 III
WGK 2
UN-Nr. 2821

Redistilled, in TE buffer equilibrated phenol, pH 7,5-8,0.
Draw solution from lower phase. Do not shake before use!
Covered with buffer. Store in the dark!

Phenol solutions for nucleic acid isolation must be buffered and adjusted to the correct pH value prior to use. ROTI®Phenol is a redistilled, in TE buffer equilibrated readytouse phenol.

ROTI®Phenol has been successfully tried and tested for isolating nucleic acids in many research laboratories. This quality product for molecular biology replaces the time consuming preparation of phenol and subsequently any exposure to toxic vapours.
Product details
Notes on the product

€80.50/Pack Qty. 

excl. VAT. | 500 ml per Pack Qty.

Art. No. 0038.3

Available from stock Karlsruhe
Delivery fast, simple and reliable!
from 6 Pack Qty. €76.48/Pack Qty.
from 24 Pack Qty. €72.45/Pack Qty.
Carl Roth subscription service

Now recurring orders conveniently delivered as a subscription!

With the new Carl Roth Replenishment Service you can let products be ordered automatically which you need regularly in your lab!

How it works:
1

Put all products for your subscription in the desired quantity in the basket.

2

In the shopping cart, select the option "Order shopping cart as subscription" Order as subscription.

3

Set Starty point and interval for your subscription and submit order!

By the way: Through your account you can customize or delete your subscriptions anytime.

Product details


  • Reduce exposure to toxic chemicals
  • Prepared from phenol of highest purity
  • Packed under argon for maximum stability
  • Successfully tried and tested in many research laboratories


Please note our Technical Information Brochure on the Internet next to the products:

Phenolic DNA Isolation
Background and protocol


Mechanism

Phenol and chloroform lead to denaturation of proteins which accumulate in the interphase. Isoamyl alcohol prevents foaming and very efficiently inhibits RNAses.
For distinct phase separation, ROTI®Aqua-Phenol needs a pH of ≤4.0 in the aqueous upper phase. If needed, the upper phase may be acidified by adding 1-2 drops of 1 N HCl.

Draw solution from lower phase. Do not shake before use!



ROTI®Phenol ready-to-use, for the extraction of nucleic acids

Phenol solutions for nucleic acid isolation must be buffered and adjusted to the correct pH value prior to use. ROTI®Phenol is a redistilled, in TE buffer equilibrated readytouse phenol.

ROTI®Phenol has been successfully tried and tested for isolating nucleic acids in many research laboratories. This quality product for molecular biology replaces the time consuming preparation of phenol and subsequently any exposure to toxic vapours.


Mechanism

Addition of 1 volume ROTI®Phenol and thorough mixing. Phenol leads to denaturation of proteins which accumulate in the interphase. Following centrifugation, the nucleic acid containing solution may be retrieved as upper phase.



ROTI®Phenol
Selected quantity:   0
  1. Subtotal:  0.00
Order No. Pack Qty. Pack. Price Quantity
0038.1 100 ml glass €26.50
0038.2 250 ml glass €52.50
0038.3 500 ml glass €80.50
Available from stock Karlsruhe
Available at short notice
Not available
Delivery date currently unknown
Selected quantity:   0
  1. Subtotal:  0.00

Downloads


Certificates of Analysis

You can search for and download your certificate of analysis for the selected product here. Please provide your batch number.
The following analysis certificates have been found:

Notes on the product

Bottled under argon.

0 Reviews