Naar de inhoud springen Naar het navigatiemenu springen

Potassium dichromate solution

1/24 mol/l - 0,25 N, volumetric standard solution, for COD determination
Icon_EVE-EUD Please consider that this product might be liable to some legal sanctions as for example to obtain an end user declaration or the prohibition of some applications. For details please do contact your counterpart in our sales department!
Mogelijke gevolgen: veroorzaken allergieën, kankerverwekkend (carcinogeen), verandering erfelijk materiaal (mutageen), brengt de voortplanting in gevaar en vruchtbeschadigend (reprotoxisch) of orgaanbeschadigend Veiligheid: voor het werk met dergelijke stoffen moet men zich goed informeren; veiligheidskleding en handschoenen, oog- en mondbescherming of adembescherming dragen.
Danger
H340-H350-H360FD-H373-H412-EUH208
i may cause genetic defects, may cause cancer, may damage fertility. May damage the unborn child, may cause damage to organs through prolonged or repeated exposure, harmful to aquatic life with long lasting effects
P273 P280 P304+P340 P308+P313
i avoid release to the environment, wear protective gloves/eye protection, IF INHALED: Remove person to fresh air and keep comfortable for breathing, IF exposed or concerned: Get medical advice/attention
VE
Verp.
Density (D) 1,008 g/cm³
Boiling point (bp) 100 °C
Melting point (mp) 0 °C
WGK 3
CAS No. 7778-50-9


69,80 €/VE 

Excl. btw | 1 l Per VE

Bestelnr. P721.1

Op voorraad
Vrij van verzendingskosten vanaf 250 €
Snelle en betrouwbare levering!
Vanaf 6 VE 66,31 €/VE
Vanaf 24 VE 62,82 €/VE
Potassium dichromate solution
Geselecteerde hoeveelheid:   0
  1. Tussentotaal:  0.00
Bestelnr. VE Verp. Prijs Hoeveelheid
P721.1 1 l plastic

69,80 €

Op voorraad
Beschikbaar
In bestelling
Niet meer verkrijgbaar
Leveringsdatum onbekend
Geselecteerde hoeveelheid:   0
  1. Tussentotaal:  0.00

Downloads / MSDS


Algemene informatie

Determination of chemical oxygen demand (COD)

COD (chemical oxygen demand) is a measure of all the oxidisable components in water under specific conditions. The water sample is mixed with sulphuric acid and heated together with a defined quantity of potassium dichromate, with silver sulphate added as the catalyst. Chloride must be removed beforehand or masked with mercury sulphate. The remaining potassium dichromate is measured by means of titration, using an ammonium iron(II) sulphate solution and ferroin as the indicator. The equivalent amount of oxygen can then be calculated from the amount of potassium dichromate that is used up.


Volumetric Standard Solutions

A volumetric standard solution is a solution containing a precisely known concentration of a substance. The concentration of a volumetric standard solution is determined using a primary standard, which is accurately weighed and dissolved to make a specific volume. Volumetric standard solutions are made using reagent-grade (p.a.) substances as source materials.


Volumetric Standard Solutions, ready-to-use

The advantages of this over making them yourself are:

  • Manufactured and tested using modern manufacturing and analytical methods
  • Ready-to-use solutions
  • High accuracy for precise analyses
  • Application of NIST-certified reference substances for checking
  • Connection to standard titrators is possible


Analysecertificaten

Hier kunt u uw analysecertificaat voor het geselecteerde product zoeken en downloaden. Geef een chargenummer op.
De volgende analysecertificaten werden gevonden:

Type analysis

Amount-of-substance conc. (20 °C)1/24 mol/l ±0.2 %
Titer0.998-1.002