LuciPac®A3 Aqua, 100 stuks

Van  Kikkoman
for hygiene control of liquids
Icon_ready-to-use Ready-to-use products and reagents
VE
Verp.
Storage temp. +4 °C
Transport temp. ambient temp.

20 LuciPac®A3 Aqua each are packed in a resealable aluminium bag. Store in a dark place.
For testing for the contamination of liquids by ATP/ADP/AMP measurement using Lumitester PD30 and SMART.

For the reliable monitoring of dry and moist surfaces as well as solutions in the manufacturing industry, in the food and feed sector, in patient care and nursing, in gastronomy and trade, in training and in many other areas.
Productdetails

564,40 €/VE 

Excl. btw | 100 stuks Per VE

Bestelnr. 1ENK.2

In productie
Vrij van verzendingskosten vanaf 250 €
Vanaf 6 VE 536,18 €/VE
Vanaf 24 VE 507,96 €/VE

Productdetails


For the reliable monitoring of dry and moist surfaces as well as solutions in the manufacturing industry, in the food and feed sector, in patient care and nursing, in gastronomy and trade, in training and in many other areas.

Alle voordelen:
  • Quick and easy sampling
  • Simple and fast measurement within seconds
  • Sensitive and reproducible measurement
  • Measurement of all forms - ATP, ADP and AMP

Let op

LuciPac®A3 is not suitable for the detection of virus contamination.


Why A3 assay (ATP+ADP+AMP)?
A3 detects ATP+ADP+AMP offering higher sensitivity to find microorganisms and biofilms that others miss. Just as fast and easy to use as conventional tests, but its advanced chemistry produces superior detection to uncover contaminants that you may be missing.



LuciPac®A3 Aqua for hygiene control of liquids
Gebruiksinstructies

Remove the sample collector (green holder) from the tube.
Dip the red comb into the liquid to be analysed.
Put the sample collector back into the tube. Then press the pin downwards to open the reaction capsule.
Shake the LuciPac®A3 Aqua horizontally several times so that all the liquid flows into the lower reaction capsule.
Insert the entire LuciPac®A3 Aqua into the measuring chamber of the Lumitester PD30 or SMART and close the measuring chamber cover.
Press the ENTER key on the control panel to start the measurement process. The measurement results are displayed after 10 seconds.
Remove the sleeve of the LuciPac®A3 Aqua from the measuring chamber.



LuciPac®A3 Aqua
Geselecteerde hoeveelheid:   0
  1. Tussentotaal:  0.00
Bestelnr. VE Verp. Prijs Hoeveelheid
1ENK.1 20 stuks aluminium bag

127,95 €

1ENK.2 100 stuks aluminium bag

564,40 €

Op voorraad
Beschikbaar
In bestelling
Niet meer verkrijgbaar
Leveringsdatum onbekend
Geselecteerde hoeveelheid:   0
  1. Tussentotaal:  0.00

Downloads / MSDS

Analysecertificaten

Hier kunt u uw analysecertificaat voor het geselecteerde product zoeken en downloaden. Geef een chargenummer op.
De volgende analysecertificaten werden gevonden: