product.details.print
α-Terpinene, 100 mg, glass
Molar mass (M) 136,24 g/mol
Density (D) 0,84 g/cm³
Boiling point (bp) 173 °C
Flash point (flp) 47 °C
Melting point (mp) <-20 °C
Storage temp. -20 °C
Transport temp. ambient temp.
ADR 3 III
WGK 2
CAS No. 99-86-5
EG-Nr. 202-795-1
UN-Nr. 2319
203,20 €/VE
Excl. btw | 100 mg Per VE
Bestelnr. 8038.2
Productdetails
Certificates of analysis with chromatogram can be found as English version - recognisable by “_EN.pdf”.
α-Terpinene ROTICHROM® GC
- Tussentotaal: 0.00
Bestelnr. | VE | Verp. | Prijs | Hoeveelheid | |
---|---|---|---|---|---|
8038.2 | 100 mg | glass |
203,20 € |
|
|
Op voorraad
Beschikbaar
In bestelling
Niet meer verkrijgbaar
Leveringsdatum onbekend
|
- Tussentotaal: 0.00
Downloads / MSDS
Algemene informatie
U vindt nog meer aantrekkelijke aanbiedingen om uw chromatografielaboratorium te vervolledigen op onze Chromatografie pagina!
For reference substances
- HPLC-chromatogram, TLC-chromatogram and GC-chromatogram respectively
- Reference substances
ROTICHROM® HPLC/TLC/GC
Pure reference substances are essential for precise analysis. They are used for identifying compounds by retention time, for calibrating detectors, and for eliminating errors in quantification of the sample compounds.
Peak areas are proportional to sample quantity in all chromatographic methods. For precise quantitative analysis, however, it is necessary to calibrate the detector as the signal may significantly vary with different substances.
To avoid errors during sample preparation and injection, an internal standard should be used in any case. The standard must not be present in the sample, however, its chemical and physical properties ought to be the closest possible to the analytical targets. It must be well resolved in the chromatogram within the same range of retention time as the sample. Before sample analysis, a given volume of standard is added, and all clean-up procedures are made with the sample containing the standard. Quantitative errors may be compensated by comparing the peak-areas of the sample with that of the internal standard.
Reference Substances for GC
ROTICHROM® GC
Carl ROTH offers an extensive range of reference substances for gaschromatography from the substance groups of alkanes, alcohols, ketones, esters, aromatic compounds, and much more. Their GC purity allows an accurate analysis.
Certificates of analysis of ROTICHROM® GC substances are prepared with GC chromatogram.
Analysecertificaten
Type analysis
Purity (GC) | ≥95 % |