product.details.print
Dibutylamine in xylene
0,1 mol/l - 0,1 N, volumetric standard solution
H226-H304-H312-H315-H319-H331-H335-H373
flammable liquid and vapour, may be fatal if swallowed and enters airways, harmful in contact with skin, causes skin irritation, causes serious eye irritation, toxic if inhaled, may cause respiratory irritation, may cause damage to organs (kidney, liver, central nervous system) through prolonged or repeated exposure
P210 P260 P280 P301+P310 P303+P361+P353 P331
keep away from heat, hot surfaces, sparks, open flames and other ignition sources. No smoking, do not breathe dust/fume/gas/mist/vapours/spray, wear protective gloves/protective clothing/eye protection/face protection, IF SWALLOWED: Immediately call a POISON CENTER/doctor, IF ON SKIN (or hair): Take off immediately all contaminated clothing. Rinse skin with water [or shower], do NOT induce vomiting
VE
Verp.
Density (D) 0,86 g/cm³
Boiling point (bp) 139,1 °C
Flash point (flp) 27 °C
Melting point (mp) -47,8 °C
ADR 3 III
WGK 2
UN-Nr. 1992
Boiling point (bp) 139,1 °C
Flash point (flp) 27 °C
Melting point (mp) -47,8 °C
ADR 3 III
WGK 2
UN-Nr. 1992
170,95 €/VE
Excl. btw | 1 l Per VE
Bestelnr. 2998.1
Op voorraad
Vrij van verzendingskosten vanaf 250 €
Snelle en betrouwbare levering!
Vanaf 6 VE
162,40 €/VE
Vanaf 24 VE
153,86 €/VE
In het winkelmandje
In het winkelmandje
Dibutylamine in xylene
Geselecteerde hoeveelheid:
0
- Tussentotaal: 0.00
In het winkelmandje
Bestelnr. | VE | Verp. | Prijs | Hoeveelheid | |
---|---|---|---|---|---|
2998.1 | 1 l | glass |
170,95 € |
|
|
Op voorraad
Beschikbaar
In bestelling
Niet meer verkrijgbaar
Leveringsdatum onbekend
|
Geselecteerde hoeveelheid:
0
- Tussentotaal: 0.00
In het winkelmandje
Downloads / MSDS
Algemene informatie
Volumetric Standard Solutions
A volumetric standard solution is a solution containing a precisely known concentration of a substance. The concentration of a volumetric standard solution is determined using a primary standard, which is accurately weighed and dissolved to make a specific volume. Volumetric standard solutions are made using reagent-grade (p.a.) substances as source materials.
Volumetric Standard Solutions, ready-to-use
The advantages of this over making them yourself are:
- Manufactured and tested using modern manufacturing and analytical methods
- Ready-to-use solutions
- High accuracy for precise analyses
- Application of NIST-certified reference substances for checking
- Connection to standard titrators is possible
Analysecertificaten
Type analysis
Amount-of-substance conc. | 0.1 mol/l ±0.6 % |
Titer | 0.994-1.006 |